Process, Florida statutory studies, and how we work. If your question isn't here, book the 15-minute call — it goes to an engineer.

ABOUT RESERVE STUDIES

A 30-year forecast of the repair and replacement costs for every common element your association owns — roads, roofs, pools, walls — with a funding plan that spreads those costs fairly over time. It's the document your board budgets on. Ray Engineering has prepared them for over 500 communities across the Southeast, and our engineers hold the CAI Reserve Specialist designation.

Industry practice is every three to five years, with lighter site-visit updates in between. Component conditions and construction costs both move — a decade-old study is a historical document, not a budget tool.

Typically six to eight weeks from signed proposal to final sealed report: scope and records review, field inspection, draft for your board's comments, then the final under a licensed P.E.'s seal. Start counting backward from your budget adoption date.

The basics: governing documents, any prior reserve study, current budget and reserve balance, and site access for the inspection. We'll walk you through the list on a 15-minute scoping call — most boards have everything on hand.

A Ray engineer — the same person who writes your report. No subcontracted inspectors, no analysts working from photos someone else took. Meet the team on our Team page; they're all named.

FLORIDA STATUTORY STUDIES

A Structural Integrity Reserve Study examines the reserve funding required for a building's structural components. Florida enacted the requirement in 2022 (SB 4D) and has amended it since; under current law it applies to condominium and cooperative buildings three stories or higher, must be completed at least every ten years, and is also required before a developer turns over control to the association. Whether and when it applies to your building depends on current statute — we confirm your specific obligations as part of scoping.

Eight element categories: roof, structural systems, fireproofing and fire safety systems, exterior painting and waterproofing, plumbing, electrical systems, windows and exterior doors (as assigned by your governing documents), and any other element over $10,000 whose condition affects structural integrity. Each is accounted for separately in the funding plan.

Under current Florida law, generally no — structural reserve funds must be collected on schedule and used for their named purpose. The days of waiving reserves by vote are over for these components. Confirm the specifics for your association with your counsel and your engineer.

A Milestone Inspection asks whether the building is structurally sound right now — it's a health exam. A SIRS asks whether the building is financially prepared for its structural future — it's a retirement plan. Both involve engineers; satisfying one does not satisfy the other. We wrote a plain-English primer on exactly this in Field Notes.

Yes, in both directions that matter. A current SIRS documents the structural health of the building — which supports property-value assessments and buyer confidence in unit sales, and gives insurers a clear basis for underwriting instead of assumptions. Boards increasingly find the study pays for itself outside the statute that requires it.

Because Florida's requirements have been amended more than once and the worst outcome is a board planning around a date that's since changed — we've seen published deadlines go stale on other firms' websites. We track the current statute as part of our practice (that's what Statute Watch is), and we confirm your building's live obligations directly.

WORKING WITH US

Flat fee, quoted before work starts, tied to your property's scope. No hourly meter, no change-order surprises — the number you approve is the number you pay.

Offices in the greater Atlanta and Tampa Bay areas, with professional engineering licensure spanning twelve states. Georgia and Florida are the core practice.

Yes — two of our engineers are FAA Part 107 licensed pilots, and drone-assisted façade and roof surveys are part of our Florida condominium practice where access or height makes them the right tool.